The following article will guide you through using the C99-T10 catenary cantilevers in Lineardraft, by providing you with:
- An annotated example with all limits for user adjustable values
- The system height and reach ranges for using the cantilevers in your design
C99-T10-301 Pull Off Cantilevers
Design Limits
Please note: Where design limits are not available on the drawing, design limits have been provided externally, these are marked in bold.
Standard:
- Minimum System Height: 360mm
- Maximum System Height: 800mm
- Minimum Reach: 1650mm
- Maximum Reach: 3100mm
C99-T10-311 Push Off Cantilevers
Design Limits
Please note: Where design limits are not available on the drawing, design limits have been provided externally, these are marked in bold.
Standard:
- Minimum System Height: 360mm
- Maximum System Height: 800mm
- Minimum Reach: 1000mm
- Maximum Reach: 3100mm