The following article will guide you through using the C99-T02 reduced encumbrance contenary cantilevers in Lineardraft, by providing you with:
- An annotated example with all limits for user adjustable values
- The system height and reach ranges for using the cantilevers in your design
C99-T02 Reduced Pull Off Contenary Cantilevers

Design Limits
Please note: Where design limits are not available on the standard drawing, they have been provided by an external source, and are marked below in bold.
Standard:
- Minimum System Height: 600mm
- Maximum System Height: 1500mm
- Minimum Reach: 1857mm
- Maximum Reach: 3710mm
C99-T02 Reduced Braced Pull Off Contenary Cantilevers

Design Limits
Please note: Where design limits are not available on the standard drawing, they have been provided by an external source, and are marked below in bold.
Standard:
- Minimum System Height: 600mm
- Maximum System Height: 1500mm
- Minimum Reach: 1857mm
- Maximum Reach: 5060mm